Drawings & engineering

STEP & IGES: online inspector for .step .stp .iges .igs files

Inspect STEP assemblies and external component references, plus IGES metadata and entity counts.

Formats
  • .step
  • .stp
  • .iges
  • .igs
STEP & IGES01 / 03

STEP & IGES01 / 03

Viewing STEP & IGES in Vormio, screenshot 1 of 3

Capabilities

What it reads and its limits

Browse STEP (.step, .stp) and IGES (.iges, .igs) files right in the folder: who made them with which software, their units and application protocol, which parts an assembly is made of, and which external component files it references. Files always stay read-only.

  • STEP: the inspector lists the header (author, organization, originating system, time) and the application protocol (AP203, AP214, AP242), products with their part numbers, and entity counts by type, most frequent first. Double-click to open the assembly tree: components show their instance names in the assembly; the first two levels are expanded, deeper ones open on demand.
  • External components: an assembly can keep its parts in other files (written as a file name plus directory, as the CAx-IF recommended practices for external references describe). These files are listed as references, and Vormio marks the ones it cannot find. Documents attached to a product, such as its drawing as a PDF, are listed as external documents; a document known only by its number, with no file name, is not listed.
  • IGES: the first line of the Start section; the Global section's product ID, native system, units, author, organization and time; Directory entity counts by type, with names for common types. Files named by external reference entities (type 416) are listed as references, and Vormio marks the ones it cannot find. An entity that gives only a name and no file is not listed, and a note in the inspector says so.

This version draws no 3D models and no thumbnails; the grid shows the format icon. Drawing STEP and IGES geometry takes a CAD geometry kernel. occt-import-js (OpenCascade compiled to WebAssembly) reads both formats, but it generates code while running, and the desktop app's security policy does not allow that, so this version leaves it out. A later version may add it.

Try the samples

  • assembly.step: an assembly whose two components place the same part; the assembly tree shows Twin blocks with Block 1 and Block 2.
  • external.stp: an AP242 assembly whose components live in other files; parts/base.step is found and parts/arm.step is missing on purpose; its drawing bracket-drawing.pdf is listed as an external document.
  • bracket.step: an AP203 assembly with part numbers; cylinder.step: an AP214 part and its entity counts.
  • cylinder.iges and line.iges: the IGES Global section, units in millimeters, and named entity types.
  • mislabeled.igs: a STEP part saved as .igs, read by its content, with a note in the inspector.
  • external.iges: places line.iges through an external reference entity (416), and line.iges is listed as a reference. A second external reference gives only the name BOLT_M6, and a note in the inspector says so.

Large files and limits

Files are read in chunks, counting structure without building geometry, even at hundreds of MB. The assembly tree and references stop at 50,000 records, while entity counts still cover the whole file. The inspector lists up to 1,000 products, and the assembly tree is in the viewer.

When a file is empty, is not STEP or IGES, was not saved completely or is damaged, the inspector says which, rather than showing a partial result. When the extension does not match the content (for example a STEP file saved as .igs), the content decides and a note says so. Compressed IGES files are not supported.

The extension at the end of a STEP document ID decides whether it is a file name or a document number. An ID with an extension of 3 to 16 characters counts as a file name. Of the two-letter extensions, only JT, PS, AI, GZ and 7Z count, since other two-letter suffixes are usually revisions (for example Rev.AB). Creo files with a version number (for example bracket.prt.3) count too. A three-letter revision (for example Rev.ABC) is taken for a file name, listed as a reference and marked as missing.

The samples are CC0 files from CADProps and CADFormats plus scripted assemblies, parts and external references; sources are in the samples' README.txt.

Where to inspect

Choose how to inspect your files

Start in your browser

The web app reads one local folder at a time. UID / GUID references are marked “Not checked”.

Working across folders?

Desktop links multiple folders, filters by properties, shows what references a file and watches for changes.

Related guides

Related guides

Related formats

Related formats